Apparatus
for Soil Tests with details
1. Sieves – IS 460 Part –
1,2,3
2. Measuring Cylinder – IS
878-1956
3. Casagrande Cup – IS
9259-1979
Drop height – 10mm, Turning
Crank ratio 2 revolutions per second.
4. Cone Penetrometer – IS 11196-1985
a.
Cone - Height – 35mm, Upper Dia – 5mm
b.
The mass of the plunger along
with its components and cone shall be 80 ± 0.5 g.
c.
The penetration of cone after 5
seconds shall be noted.
5. Proctor Mould – IS
10074-1982
a.
1000 cc mould - Internal Dia – 100±0.4
mm, Outer Dia – 112 mm, Height – 127.3±0.2mm
b.
2250 cc mould - Internal Dia – 150±0.4
mm, Outer Dia – 162 mm, Height – 127.3±0.2mm
6. CBR Mould – IS 9669-1980
a.
Mould- Internal Dia - 150±0.1mm, Outer
Dia – 160mm, Height - 175±0.1mm
b.
Collar - Height – 60mm
c.
Spacer Disk - Height – 47.7mmm Dia –
148mm
d.
Annular weight (2.5KG) - Dia – 147mm,
Hole at centre – 53mm dia
e.
Perforated Plate - Dia – 148mm,
Thickness – 5mm, Max 42 holes of 1.5mm dia
f.
Penetration Plunger - Dia - 50±0.1mm,
height – 100mm approx.
7. Rammer 4.9 KG – IS 9189-1979
Height of fall -
450±0.5mm, Rammer Weight – 4.9±50gm
8. Rammer 2.6 KG - IS
9198-1979
Height of fall -
310±0.5mm, Rammer Weight – 2.6±25gm
9. FDD Test Apparatus
a. Cylindrical calibrating
Container for small pouring cylinder.
Dia – 100mm, Internal Depth – 150mm, Volume Accuracy –
0.25%
Flange – 50mm wide approx and 5mm thick
b. Cylindrical calibrating
container for large pouring cylinder.
Dia – 200mm, Internal Depth – 250mm, Volume Accuracy –
0.15%
Flange – 75mm wide approx and 5mm thick
c. Metal Tray with central
hole for Small Cylinder.
300 mm square and 40 mm deep with 100 mm hole in the centre.
d. Metal Tray with central hole
for Large Cylinder
450 mm square and 50 mm deep with 200 mm hole in the centre.
e. Small Pouring Cylinder
Total Height – 380 mm, Internal Diameter – 115mm
f.
Large Pouring Cylinder
Total Height – 610mm, Internal Diameter – 215 mm
g.
Sand - 1 mm passing and 600 micron
retained.
10. Moisture Apparatus -
11. CBR Machine – Penetration
Rate 1.25mm per minute.
Apparatus
for Aggregates Tests with details
1. AIV MACHINE – IS 2386 Part
4
a.
Total wt. Of AIV machine - Between 60 to 45 KG.
b.
Base - 22 to 30 KG.
c.
Cylindrical Steel Cup - Diameter 102mm
and Depth 50mm
d.
Metal tup or hammer – 13.5 to 14 KG,
Diameter 100mm, height 5cm
e.
Height of fall - 380±5.0mm
f.
Measure - Diameter 75mm, depth 50mm.
g.
Tamping rod - Diameter 10mm, Length
230mm.
2.
FI & EI test apparatus – IS 2386 Part 1
3. 10% fines value test
apparatus - IS 2386 Part 4
a.
Tamping Rod – Diameter 16mm, Length 45
to 60mm
b.
Cylindrical metal measure – Diameter
11.5cm, Height 18cm
4. Los Angeles Machine – IS
2386 Part 4
a.
Hollow Steel Cylinder – Diameter 700mm,
Inside Length 500mm.
b.
Abrasive Charge – Diameter 48mm, Weight
between 390 to 445 gm.
5.
Wire basket – IS 2386 Part 3 – Not more
than 6.3 mm mesh.
6.
Pycnometer – About one litre capacity
having a metal conical screw top with a 6mm diameter hole at its apex.
7.
Density Bottle
Apparatus used for Cement and Concrete Test
1.
Sieve – IS 4031 Part 1 - 90µm mesh for
dry sieving.
2.
Balance – Capable of weighting up to 10g
to the nearest 10 mg.
3.
Brush – A nylon or pure Bristol brush,
preferably with 25 to 40 mm bristle. For
cleaning the sieve.
4. LE-Chatelier apparatus –
IS 5514 (1969)
a.
Internal diameter of the mould
30mm±0.3mm
b.
Wall thickness of mould
0.5mm±0.05mm
c.
Height of mould 30mm±0.15mm
d.
Split – 0.5mm max
e.
Pair of Glass plate of about 35
mm X 35 mm.
f.
Weight - 75gm
approx
5. Moulds – conforming to IS
10086-1982
6. Gauging Trowel – IS
10086-1982
7. Autoclave – As per IS 4031
Part -3
8. Length Comparator –
conforming to IS 9459-1980
9. Vicat Apparatus – IS
5513-1976
a. Needle ‘C’ – Dia - 1.13±0.05mm, Length excluding the hilt - 50±1mm, Weight -
9±0.5g.
b. Needle ‘F’ – Dia -1.13±0.05mm, Length excluding the hilt – 30±1mm, Circular
cutting edge 5±0.1mm in diameter, Weight - 9±0.5g.
c. Plunger ‘G’ – Dia - 10±0.05mm, Length - 50±1mm, Weight - 9±0.5g.
d. Total mass of moving unit, when in use, complete with all
attachments, that is the cap and rod together with either needle C or Needle F
or plunger G, shall be 300+1g.
http://setestindia.com/vicat-needel-apparatus.html
ReplyDeletehttp://www.setestindia.com/
ReplyDelete